Data Center Expertise

Mission-Critical Expertise

Prism Electric has become a trusted partner for some of the most complex and confidential data center projects across Texas and Oklahoma. From greenfield core and shell builds to high-density fit-outs and live upgrades, our teams are experienced in powering the infrastructure that keeps the digital world moving.

We understand the unique demands of mission-critical environments—tight schedules, zero tolerance for downtime, and precision in every installation. Our field crews and engineering teams work seamlessly to deliver reliable results, whether it’s coordinating phased construction, handling redundant power systems, or managing multi-voltage installations.

Though client confidentiality is essential, we’re proud of the depth and diversity of our data center portfolio. Below is a selection of representative projects completed since 2023:

  • Project Type & Location

    Fit Up & Fit-Out (Phase 1&2)

    Central Texas

    20 MW

    Data Center Expertise

    Project Type & Location

    Fit Up & Fit-Out (Phase 1&2)

    Central Texas

    20 MW

    Contract Amount

    Fit Up - $3,202,353
    Fit Out - $12,685,897

    Start/End Date

    Fit Up - End 05/25
    Fit Out - 12/23-11/25

    Contract Amount

    Fit Up - $3,202,353
    Fit Out - $12,685,897

    Start/End Date

    Fit Up - End 05/25
    Fit Out - 12/23-11/25

    Scope Highlights

    Two 10 MW Halls (20MW Total)
    Furnished/installed conduit & wire for multi-voltage systems

  • Project Type & Location

    Fit Up, Fit-Out, & Core & Shell

    North Texas

    110 MW

    Data Center Expertise

    Project Type & Location

    Fit Up, Fit-Out, & Core & Shell

    North Texas

    110 MW

    Contract Amount

    $124,000,000

    Start/End Date

    04/25-04/27

    Contract Amount

    $124,000,000

    Start/End Date

    04/25-04/27

    Scope Highlights

    110MW of connected DC load, multi-phase build out, full Interior Fit-Out

    • Over 3,000,000’ of wire (591 miles)
    • 22-Tiered Cable Tray Conveyance System
    • 912,000’ of Pipe (172 miles)
    • Almost 3 miles of busduct
  • Project Type & Location

    Fit-Out

    Central Texas

    48 MW

    Data Center Expertise

    Project Type & Location

    Fit-Out

    Central Texas

    48 MW

    Contract Amount

    $24,308,200

    Start/End Date

    11/24-11/25

    Contract Amount

    $24,308,200

    Start/End Date

    11/24-11/25

    Scope Highlights

    48MW – Full interior fit-out

  • Project Type & Location

    Fit-Out

    North Texas

    72 MW

    Data Center Expertise

    Project Type & Location

    Fit-Out

    North Texas

    72 MW

    Contract Amount

    $33,370,931

    Start/End Date

    06/24-11/25

    Contract Amount

    $33,370,931

    Start/End Date

    06/24-11/25

    Scope Highlights

    72MW total connected load, 34.5 kV, multiple turnkey fit-out for TFO facility

  • Project Type & Location

    General Electrical

    Oklahoma

    2 MW

    Data Center Expertise

    Project Type & Location

    General Electrical

    Oklahoma

    2 MW

    Contract Amount

    $6,123,622

    Start/End Date

    06/23-12/24

    Contract Amount

    $6,123,622

    Start/End Date

    06/23-12/24

    Scope Highlights

    2MW – Full electrical + low voltage

  • Project Type & Location

    General Electrical

    Central Texas

    30 MW

    Data Center Expertise

    Project Type & Location

    General Electrical

    Central Texas

    30 MW

    Contract Amount

    $5,000,000

    Start/End Date

    02/25-08/25

    Contract Amount

    $5,000,000

    Start/End Date

    02/25-08/25

    Scope Highlights

    30 MW Hyperscale facility

  • Project Type & Location

    Core & Shell

    North Texas

    300K
    SQ. FT.

    Data Center Expertise

    Project Type & Location

    Core & Shell

    North Texas

    300K
    SQ. FT.

    Contract Amount

    $28,000,000

    Start/End Date

    02/25-05/26

    Contract Amount

    $28,000,000

    Start/End Date

    02/25-05/26

    Scope Highlights

    Demo & rebuild of 300,000 sq. ft. facility

  • Project Type & Location

    Core & Shell

    Central Texas

    503K
    SQ. FT.

    Data Center Expertise

    Project Type & Location

    Core & Shell

    Central Texas

    503K
    SQ. FT.

    Contract Amount

    $25,000,000

    Start/End Date

    08/24-2/26

    Contract Amount

    $25,000,000

    Start/End Date

    08/24-2/26

    Scope Highlights

    Ground-up construction-Improvements & construction of new 2-story 503,000 Sq.Ft. building.